| Product | Electromagnetic flowmeter |
| Model | FMC240 |
| Diameter nominal | DN15~DN1200 |
| Nominal pressure | DN15 – DN250, PN ≤1.6MPa; DN300 – DN1000, PN ≤1.0MPa; DN1200, PN ≤0.6 MPa; Higher pressure can be customized |
| Accuracy | ±0.5% F.S. (Flow speed > 1m/s); ±0.5% F. S. ±2mm/s (Flow speed <1m/s) |
| Liner material | Neoprene (CR), Polyurethane (PU), PTFE (F4), PFEP (F46), PFA |
| Electrode material | 316L Stainless Steel, Hastelloy C, Hastelloy B, Ti, Ta, Pt |
| Medium temperature | Neoprene: -10…+60℃ Polyurethane: -10…+60℃ PTFE/FEP: -10…+120℃ PFA: -10…+180℃ |
| Power supply | 85-245VAC,50/60Hz, 22VDC-26VDC |
| Electrical conductivity | Water min.20μS/cm;other medium min.5μS/cm |
| Structure type | Compact type, Remote type |
| Ingress protection | IP65 for converter, IP68 for sensor |
| Product standard | JB/T 9248-1999 Electromagnetic Flow Meter |
| Where: E-Induced electromotive force K-Meter constant B-Magnetic induction density V-Average flow speed in cross-section of measuring tube D-Inner diameter of measuring tube |
![]() |












Đánh giá
Chưa có đánh giá nào.